Boiler pump problem

  • Location: Upper Norwood
  • Hired: Goldcrest Maintenance Service
  • Trade: Central Heating
Job Description

My boiler makes a lot of noise, I suspect its the pump that may be old and vibrating more than it should which is causing the problem. If this is the case, I would like to replace it and fit one in such a way that it creates minimal noise as the unit is located in a bedroom.

Boiler service

  • Location: Stoke Newington
  • Hired: P3 Heating Services
  • Trade: Central Heating
Job Description

Need to get my boiler serviced please.
last done 1 1/2 years ago.

Replace boiler

  • Location: Blackheath
  • Hired: Lambert plumbing, heating & gas
  • Trade: Central Heating
Job Description

We'd like to replace the existing boiler asap

Gax Boiler repair

  • Location: Islington
  • Hired: P3 Heating Services
  • Trade: Central Heating
Job Description

The fan in our Baxi Combi 105 HR boiler is displaying a fault and we're not getting hot water all of the time. Think the part needs replaced and the boiler repaired

move 4 radiators

  • Location: Walthamstow
  • Hired: Calorific
  • Trade: Central Heating
Job Description

Just bought a house. Radiators are in silly places. In four rooms they need to be moved to under the windows. Two of the windows are bays. Gas-fired ch.

No hot water unless the heating is on - boiler is fine

  • Location: Chigwell
  • Hired: JSG Plumbing & Heating Ltd
  • Trade: Central Heating
Job Description

Might be the termostate but the boiler and heating is fine but no hotwater if heating is switched off.

Clean heat exchanger on combi boiler

  • Location: Manor Park
  • Hired: L.D Plumbing and Heating
  • Trade: Central Heating
Job Description

Hi

The hot water on a 7 month old 24kw Potterton Titanium combi boiler is playing up. It appears that the secondary heat exchanger needs a clean.

The hot water gets too hot and then the boiler stops heating for a few seconds and then heats and this happens repeatedly. The effect on the hot water tap is that the hot water comes and goes every few seconds. Heating is working ok.

It is probably my fault as I replaced some radiators after the boiler was installed but waited too long to add inhibitor!

FYI I have just added Sentinel X400 cleaner into the system and will add X100 inhibitor after I drain the system in a few days/weeks. Hopefully this will mean no more problems hot water problems in the future once the heat exchanger has been cleaned.

I am looking for a quote for someone to clean (not replace) the heat exchanger. Gas Safe people only please.

* Added 28th April, 2013 :
Additional information:

- I do have a magnaclean fitted.

- I haven't considered the warranty option yet because I thought that as I hadn't taken proper precautions before fitting my new radiators it wouldn't be covered.

- The system had been powerflushed when the boiler was fitted back in October but I then decided to replace some of the old radiators one by one over the winter. I left 3 radiators but as I didn't add any inhibitor I guess these would have corroded over time.

- The original installer has already cleaned the heat exchanger once for me 2 months ago as a free favour and told me to run some cleaning solution and then add inhibitor but due to my lazyness in the cold weather I delayed too long and the problem returned.

- I will consider replacing the remaining 3 radiators. I haven't done this already as the pripework needs adjusting for these and I can't do that. However, my current priority is to get my hot water back.

Complete overhaul of central heating system

  • Location: Fulham
  • Hired: Gavin Clarke Contracting Services Ltd.
  • Trade: Central Heating
Job Description

Our central heating system is completely inefficient. Some of the radiators don't even come on. We would like the whole system assessed and repaired so it all works!

Fix water heater

  • Location: Lewisham
  • Hired: Reliable Heating Services Ltd
  • Trade: Central Heating
Job Description

Hot water heater not working - had been making a hissing noise for several days and today has stopped working altogether. Possibly the solonoid needs replacing?

That is an emergency job, but also looking to have a dishwasher plumbed in and a new kitchen tap installed at some point soon.

Bathroom; Pipe leaking and boiler repair/replacement

  • Location: South Norwood
  • Hired: Apolo Heating
  • Trade: Central Heating
Job Description

Bathroom located on 1st Floor of house
Pipe leaking under toilet and under sink
Combi Boiler not working repair if possible or replacement

Faculty heating pump

  • Location: Middle Park
  • Hired: Reliable Heating Services Ltd
  • Trade: Central Heating
Job Description

If I switch my heating on it only works on full.I can not turn it down.I am told the pump is calling for hot water.

BIASI boiler problem

  • Location: Walthamstow
  • Hired: precision property maintenance
  • Trade: Central Heating
Job Description

Central heating works fine, only when hot water turned on, there's a bit of noise coming from the boiled and a light indicator for "d.h.w. excessive temperature on primary circuit" comes on. The boiler is under two years old.

Boiler replacement

  • Location: Fulham
  • Hired: Lambert plumbing, heating & gas
  • Trade: Central Heating
Job Description

Corgi registered person needed to replace old gas combi boiler (and dispose of) with new combi boiler, supply and fit. Preferably with ongoing warranty / service support. May also need a couple of thermostats fitted on radiators. Price to be all inclusive and with breakdown of labour/parts. Private flat but may be rented in the future.

Boiler is currently a Ferroli f24b (I think). I have heard that Vaillant are reliable / economical but open to other advice as to the replacement.

Leak from boiler

  • Location: Tooting
  • Hired: VHC Plumbing and Heating Ltd
  • Trade: Central Heating
Job Description

Pipework in boiler appears to be leaking. Need to identify source of leak and replace pipe work as required.

Problem with i Ideal H24 boiler

  • Location: Stoke Newington
  • Hired: James Gas Services
  • Trade: Central Heating
Job Description

I recently bled the radiator in our bathroom and now the heating and water won't come on. We now have a L9 error message on the display on the boiler.

MyBuilder for Tradesmen

Sign up
Register as a Tradesman
Express interest in jobs
Choose the jobs you want
Get Shortlisted
Job posters will add you to their shortlist
Win Work, Get Feedback
Positive feedback gets you more work
"I would like to say I have had my busiest year ever since trading thanks to your site. You have put together a great site that works!"
Tim Cooper
Locations
>Rotherhithe
>Surrey Quays
>Wapping
>Tower Hill
>Limehouse
>Bermondsey
>Stepney
>Whitechapel
>Millwall
>Shadwell
>Deptford
Read about MyBuilder in the Press