Boiler service
- Location: Stoke Newington
- Hired: P3 Heating Services
- Trade: Central Heating
- Positive feedback on 16th May 13
Job Description
Need to get my boiler serviced please.
last done 1 1/2 years ago.
Replace boiler
- Location: Blackheath
- Hired: Lambert plumbing, heating & gas
- Trade: Central Heating
- Positive feedback on 15th May 13
Job Description
We'd like to replace the existing boiler asap
Gax Boiler repair
- Location: Islington
- Hired: P3 Heating Services
- Trade: Central Heating
- Positive feedback on 15th May 13
Job Description
The fan in our Baxi Combi 105 HR boiler is displaying a fault and we're not getting hot water all of the time. Think the part needs replaced and the boiler repaired
move 4 radiators
- Location: Walthamstow
- Hired: Calorific
- Trade: Central Heating
- Positive feedback on 15th May 13
Job Description
Just bought a house. Radiators are in silly places. In four rooms they need to be moved to under the windows. Two of the windows are bays. Gas-fired ch.
No hot water unless the heating is on - boiler is fine
- Location: Chigwell
- Hired: JSG Plumbing & Heating Ltd
- Trade: Central Heating
- Positive feedback on 14th May 13
Job Description
Might be the termostate but the boiler and heating is fine but no hotwater if heating is switched off.
Clean heat exchanger on combi boiler
- Location: Manor Park
- Hired: L.D Plumbing and Heating
- Trade: Central Heating
- Positive feedback on 14th May 13
Job Description
Hi
The hot water on a 7 month old 24kw Potterton Titanium combi boiler is playing up. It appears that the secondary heat exchanger needs a clean.
The hot water gets too hot and then the boiler stops heating for a few seconds and then heats and this happens repeatedly. The effect on the hot water tap is that the hot water comes and goes every few seconds. Heating is working ok.
It is probably my fault as I replaced some radiators after the boiler was installed but waited too long to add inhibitor!
FYI I have just added Sentinel X400 cleaner into the system and will add X100 inhibitor after I drain the system in a few days/weeks. Hopefully this will mean no more problems hot water problems in the future once the heat exchanger has been cleaned.
I am looking for a quote for someone to clean (not replace) the heat exchanger. Gas Safe people only please.
* Added 28th April, 2013 :
Additional information:
- I do have a magnaclean fitted.
- I haven't considered the warranty option yet because I thought that as I hadn't taken proper precautions before fitting my new radiators it wouldn't be covered.
- The system had been powerflushed when the boiler was fitted back in October but I then decided to replace some of the old radiators one by one over the winter. I left 3 radiators but as I didn't add any inhibitor I guess these would have corroded over time.
- The original installer has already cleaned the heat exchanger once for me 2 months ago as a free favour and told me to run some cleaning solution and then add inhibitor but due to my lazyness in the cold weather I delayed too long and the problem returned.
- I will consider replacing the remaining 3 radiators. I haven't done this already as the pripework needs adjusting for these and I can't do that. However, my current priority is to get my hot water back.
Fix water heater
- Location: Lewisham
- Hired: Reliable Heating Services Ltd
- Trade: Central Heating
- Positive feedback on 13th May 13
Job Description
Hot water heater not working - had been making a hissing noise for several days and today has stopped working altogether. Possibly the solonoid needs replacing?
That is an emergency job, but also looking to have a dishwasher plumbed in and a new kitchen tap installed at some point soon.
Faculty heating pump
- Location: Middle Park
- Hired: Reliable Heating Services Ltd
- Trade: Central Heating
- Positive feedback on 10th May 13
Job Description
If I switch my heating on it only works on full.I can not turn it down.I am told the pump is calling for hot water.
BIASI boiler problem
- Location: Walthamstow
- Hired: precision property maintenance
- Trade: Central Heating
- Positive feedback on 9th May 13
Job Description
Central heating works fine, only when hot water turned on, there's a bit of noise coming from the boiled and a light indicator for "d.h.w. excessive temperature on primary circuit" comes on. The boiler is under two years old.
Problem with i Ideal H24 boiler
- Location: Stoke Newington
- Hired: James Gas Services
- Trade: Central Heating
- Positive feedback on 7th May 13
Job Description
I recently bled the radiator in our bathroom and now the heating and water won't come on. We now have a L9 error message on the display on the boiler.
Fit new boiler flue
- Location: Dalston
- Hired: Evolve Property Solutions Ltd
- Trade: Central Heating
- Positive feedback on 2nd May 13
Job Description
We just had a new boiler (and flue outside) installed but the plumber who fitted it put it under my neighbour's window and it now has to be moved. We will probably need to buy new materials. Flat is ground floor basement of Victorian terrace conversion. Boiler is fitted against external wall. Can provide pictures.
Combi Boiler Replacement
- Location: Holloway
- Hired: Green Heating Resolutions
- Trade: Central Heating
- Positive feedback on 2nd May 13
Job Description
Remove existing Alpha combi boiler (dispose) and replace with new 24kw mid range combi. Gas served. Boiler serves 6 radiators in 1 bedroom flat, and obviously domestic hot water.
Quote for labour and materials
Boiler - water leakage and no central heating!
- Location: Greenwich
- Hired: Reliable Heating Services Ltd
- Trade: Central Heating
- Positive feedback on 29th Apr 13
Job Description
Hi there,
I have a Biasi Combi Boiler (bought 3 1/2 years ago) which is both leaking water and the central heating is not switching on however we still get hot water for showering/bathing etc.
I am looking for someone to quote to repair the boiler.
Thanks
Simon
Ariston - Combi Boiler
- Location: Notting Hill
- Hired: CH Westend
- Trade: Central Heating
- Positive feedback on 29th Apr 13
Job Description
Combi Boiler Ariston Boiler. Keeps fluctuating from hot to cold.
My understanding is that it needs a new Heat Regulator.
I would like an engineer to come and fix the issue.
Please give an idea of cost involved. I can pay cash. Thanks
Two thermostatics control valves need replacing
- Location: Barnet
- Hired: James Gas Services
- Trade: Central Heating
- Positive feedback on 28th Apr 13
Job Description
We have two thermostatic control valves that need replacing on our radiators. One radiator does not work and the other the valve has come off.
MyBuilder for Tradesmen
- Sign up
- Register as a Tradesman
- Express interest in jobs
- Choose the jobs you want
- Get Shortlisted
- Job posters will add you to their shortlist
- Win Work, Get Feedback
- Positive feedback gets you more work
- "Congratulating you on your efforts in helping small businesses reach more customers. We're really pleased to be registered with you."
- MS Contractors
- Locations
- >Walthamstow
- >Upper Walthamstow
- >Waltham Forest
- >Leyton Marshes
- >Leyton
- >Snaresbrook
- >Temple Mills
- >Hale End
- >Highams Park
- >Tottenham Hale
- >Wanstead
- Building jobs in Walthamstow, East London
- >Architectural Services
- >Bathroom Fitting
- >Bricklaying
- >Carpentry & Joinery
- >Carpet Fitting
- >Chimneys & Fireplaces
- >Conservatories
- >Conversions - General
- >Damp Proofing
- >Demolition & Clearing
- >Driveways
- >Electrical
- >Extensions
- >Fencing
- >Flooring
- >Garages & Sheds
- >Gas Work
- >Groundwork & Foundations
- >Handyman
- >Central Heating
- >Insulation
- >Kitchen Fitting
- >Landscape Gardening
- >Loft Conversions
- >New Builds
- >Painting & Decorating
- >Plastering
- >Plumbing
- >Restoration & Refurbishment
- >Roofing
- >Security Systems
- >Stonemasonry
- >Tiling
- >Tree Surgery
- >Windows