Rewire 4-bed victorian house in hackney - Electrical job in Dalston, East London

2Rewire 4-bed Victorian house in Hackney

Job Description

Fully rewire our Victorian house while causing a minimum of damage to baseboards and floorboards and a minimum of mess. To be completed in October 2011. Please include in quote availability for start, estimated duration of job, number of people who would be working on site, whether we would need to vacate the house during work, and preferably itemized quote.

DESCRIPTION OF THE HOUSE
-3-storey Victorian house plus cellar and attic
-approx 1922 sq. ft/179 sq. m excluding cellar and attic
-Kitchen, double-reception, 2 x toilet rooms, 2 x bathrooms, 4 x bedrooms
- No carpets
- Floorboards are NOT tongue-and-groove - just straight nailed down.
-House is inhabited but with limited furniture and no children or elderly

DESCRIPTION OF THE JOB
-Fully rewire our Victorian house while causing a minimum of damage to baseboards and floorboards and a minimum of mess.
-The house is inhabited but could be vacated for the duration of the rewiring job.
-For information: The plaster will be reskimmed and house redecorated following the rewiring, but the rewiring should cause a minimum of damage.
-quote to include white plastic fittings

Rooms
-36 × 13 amp twin sockets
-15 x Ceiling light plus switch - 4 of our own ceiling fittings plus 11 standard white plastic single bulb fittings
-15 x sets of 2-way switches for hallway and landings
-7 x Mains voltage smoke alarm
-1 x 5 ft fluorescent fitting plus light plus switch for attic
-1 x burglar alarm spur
-Reposition sky cable through cellar up to tv point
-2 x telephone points

Additional Kitchen and bathroom items
12 × White low voltage fire rated bathroom rated fittings plus
transformer lamp Etc.
1 × Boiler supply
Boiler wiring
Immersion Heater supply
2 × Shave light
4 × 4” Extract Fan (× isolation Switch)
1 × Light plus switch for cooker hood
6 × White low voltage fire rated fittings plus transformer lamp Etc.
1 set of 2 way switching
1 × Heat Detector
1 gas ignition
1 × Cooker hood supply
1 Fridge/Freezer circuit
1 × 30amp cooker circuit
1 Dishwasher supply

Cellar
3 × lighting points plus three bulk head fittings plus one switch
1 × emergency light plus switch above mains positions
3 × Twin Sockets
1 × 13 amp switch spur for sani flow system

Outside
-1 x porch light plus switch
-1 x portable door bell unit plus extra unit
-2 x sensor lights plus switch
-1 x IP rated twin socket

Mains Positions
1 × 14way 17 Edition Twin RCD Consumer unit plus necessary
breakers Etc
25 mm Meter tails Brown and Blue
Earth Block
2 x 16 mm Main to Water